ATTACK DPX LAMBDA Bedienerhandbuch Seite 21

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 51
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 20
21
a difference between flue gas temperature
and temperature in the boilers
06 : Disconnection
O
2
TAG
Function: Boiler for wood combustion is
switched off in consequence of:
O2 – indicates higher level of coal residual.
(easier start)
TAG – indicates minimum coal residual
(recommended by combustion problems –
deformed or wet fuel)
Producer: O2
Setting: O2/TAG
10 : V1 Primary air
Air (%) 85
Function: By flue gas sensor error or
oxygen sensor error it regulates adjusted
temperature. It serves as temporary
solution, until the error is removed - it is
not a standard operation function in any
case!
Producer: 85 %
Range of setting: 0 % - 100 %
11 : V2 Secondary air
Air (%) 40
Function: By flue gas sensor error or
oxygen sensor error it regulates adjusted
temperature. It serves as temporary
solution, until the error is removed - it is
not a standard operation function in any
case!
Producer: 40%C
Range of setting: 0 % - 100%
Finish
After the settings are made, the test of device is performed, correct device functions are and the
safety test is done as well.